Inncom e4 Smart Digital Thermostat

Found throughout W Hotels - the Inncom thermostat can be placed into a VIP mode that allows an increased range of temperatures - and bypasses its motion & door/window sensors.

To activate:

  • Press Display
 and hold
  • Press and Release - Off/Auto
  • Press and Release - Up Arrow 
  • Release Display button
Upon successful activation, the thermostat will display “VIP”.  By default, VIP mode is set to remain in effect for 72 hours.
image

SensorStat-DDC

To disable the motion sensor on the SensorStat-DDC thermostat:

  • Depress the On/Off and Arrow Down buttons simultaneously
  • Upon activation, “bP” will display
  • The thermostat will now stay on, regardless of activity from the motion sensor

You will need to depress the On/Off button again if the system was on when you activated bypass mode.

image